All guides

Quality · 5 min read ·

Sampling a finished CBD batch

Define the lot, locate variability and write a sampling instruction that the warehouse and laboratory can both follow.

Sealed laboratory sample vials beside blank labels.
Editorial illustration of sample handling in a laboratory.

A result represents the material that reached the laboratory. To use it for a decision about a batch, explain how that material was selected. Write a sampling instruction for the exact product and purpose. A plan to investigate a packaging problem may differ from a routine check of a stable manufacturing process.

Describe the lot and where it could vary

Start with batch boundaries, units, filling sequence and storage locations. Ask how the manufacturer accounts for interruptions, production adjustments, and material added back into the process. Decide what kinds of variation you are trying to detect. A sample from one carton might answer a question about that carton, while a batch-wide decision needs a plan linked to the wider lot. FSA MyHACCP prerequisite guidance.

Take samples using a documented method

Name the person taking the sample and describe the selection method, collection points, containers, and conditions for transfer to the lab. Record original identifiers before applying any internal sample codes. Ask the laboratory which sampling and preparation procedures are covered by its accreditation. If using pooled samples, discuss what combining material could conceal and whether the acceptance question concerns individual retail units. UKAS accreditation for laboratories that test food.

Make an exception visible

For example, a team receives an order with packs from two production lots. Create two sample records limited to the corresponding goods. If one lot has a packaging defect, record whether a separate targeted sample was taken for that issue. Keep retained units identifiable and document where they are held. When a report arrives, confirm the number of units and their lot records before approving the intended release decision. Food Standards Agency food traceability guidance.

Specify the decision the sample will support

A programme checking supplier consistency across several months has a different objective from a decision about one finished lot. Write the product and revision, lot definition, risk question, sample unit and laboratory deliverables before collecting anything. If the concern is variation within a filling run, ensure samples represent where variation may occur during packing. A retained bulk sample may help investigate production, but it leaves open what happened during fill and packaging. Where a contractual or official method applies, follow that plan and record its basis. An internal plan can be justified by prior evidence, process controls and which failures the testing should be able to detect. UKAS food laboratory accreditation guidance GOV.UK food safety management overview

Choose samples from locations that answer the question

Consider a hypothetical run split between three pallets that were filled at the beginning, middle and end of production. If a sample consists only of easy-to-reach units from the top of the last pallet, it reveals little about the earlier parts of the run. A plan might assign separately identified units to defined points across the run and use a documented selection method within each point. Preserve the link between the pallet, case and production position where it is available. When dispatch records do not link pallet order to the filling process, record the gap and look for an alternative such as timed line checks or retain samples relevant to the plan. FSA guidance on food traceability

Agree when a composite answers the wrong question

A composite can give information about the combined sample, but combining units changes what the result can establish. Imagine four equally weighted units with concentrations of 5, 5, 5 and 13 in arbitrary units. Their combined mean is 7. An internal requirement to identify whether every sampled unit is below 10 would need unit-level evidence, because the combined result would not expose the high unit. For other questions, such as the average of a suitably designed sample, a composite may be useful if the procedure is validated and documented. Agree with the laboratory how the material will be handled, reported and interpreted before finalising the plan. UKAS food laboratory accreditation guidance UKAS LAB 48 guidance on decisions and statements of conformity

Maintain identity through dispatch, arrival and retention

Record sampler, date, time, lot, pack version, originating location and each sample's seal and condition. Use a container and transport arrangement that the laboratory confirms are suitable for the matrix and analysis. Explain how receipt discrepancies are communicated and whether there is an associated retained sample for an investigation. A representative sample is weakened by unknown handling or an unreadable identity. If a seal breaks during dispatch or a lab receives an item labelled with the wrong lot, compare records and keep the identity issue visible. Subject to the applicable procedure, an affected lot can remain on hold while the sampling owner identifies what evidence can still be used. UKAS food laboratory accreditation guidance FSA guidance on food traceability

Decide what to do when evidence is incomplete

Use a receipt checklist that records which planned points were sampled and which could not be accessed. The reviewer can assess whether the collection still answers the intended question or whether an additional draw is necessary. If a sample was lost, keep it on the manifest with the reason and link a replacement to its own draw and conditions. Give the disposition owner the sampling plan, actual sample register, reports and any deviations. That lets them distinguish an apparently passing result from sufficient evidence for the stated release decision. Review recurring deviations where sampling inconvenience repeatedly concentrates testing on a small part of production. GOV.UK food safety management overview UKAS LAB 48 guidance on decisions and statements of conformity

Set aside duplicate material with a specific purpose

When a plan retains units for follow-up, state whether they can support a repeat measurement, a packaging investigation or examination of variation. Identify where each unit came from and how it is stored. A single retain taken at the end of a line may be useful for one investigation while leaving questions about the start of the run. Make the reserve sample register available to the decision owner before a result is disputed.